| View Issue Details [ Jump to Notes ] | [ Issue History ] [ Print ] |
| ID | Project | Category | View Status | Date Submitted | Last Update |
| 0005640 | OCaml | OCaml typing | public | 2012-06-08 15:43 | 2012-06-08 17:32 |
|
| Reporter | esther | |
| Assigned To | frisch | |
| Priority | normal | Severity | minor | Reproducibility | have not tried |
| Status | resolved | Resolution | fixed | |
| Platform | | OS | | OS Version | |
| Product Version | | |
| Target Version | | Fixed in Version | | |
|
| Summary | 0005640: OCaml-4: read_cmt tool not working on Windows |
| Description | Dual bug as 0005639.
The read_cmt function should use open_in_bin instead of open_in.
File typing/cmt_format.ml, line 72 |
| Tags | No tags attached. |
|
| Attached Files | |
|